Product Information
Plastic & Reconstructive Surgical InstrumentsHandle Skin Grafting Small
Precision-Balanced Surgical Stainless Steel Small Skin Grafting Knife Handle Featuring Adjustable Thickness Gauge Roller Guard and Secure Blade Clamp for Uniform Split-Thickness Skin Graft Harvesting.
Surgical Highlights
- Compact Small Blade Profile
- Calibrated Thickness Gauge
- AISI 304/410 Surgical Steel
- Fully Steam Autoclavable
What is a Handle Skin Grafting Small?
A Handle Skin Grafting Small (also known as a surgical dermatome handle or Humby/Watson small skin graft knife holder) is a specialized reconstructive surgical instrument designed to hold disposable dermatome blades for harvesting thin, uniform split-thickness skin grafts from donor sites. Its compact size provides superior control in contoured or smaller anatomical donor areas.
1. Surgical Assembly & Harvesting Protocol
Stage 01Sterile Blade Loading
Unlock the retaining clamp, insert a sterile disposable skin grafting blade cleanly onto the alignment pins, and lock securely.
Stage 02Graft Thickness Calibration
Rotate the knurled micrometer adjustment knobs symmetrically to set the exact gap between the roller guard and blade edge.
Stage 03Controlled Graft Harvesting
Apply smooth, steady oscillatory strokes across the lubricated donor skin surface to harvest an even split-thickness graft.
Stage 04Blade Disposal & Sterilization
Safely eject the used blade into a sharps container, wash the handle thoroughly, and prepare for hospital steam autoclaving.
2. Technical Specifications & Overview
Parameter Specification Details Product Name Handle Skin Grafting Small (Watson / Humby Pattern) Material Grade Medical-Grade Surgical Stainless Steel (Corrosion Resistant) Size Profile Small / Compact Format for Localized & Contoured Donor Sites Guard Mechanism Adjustable Smooth Roller Guard with Calibrated Depth Screws Finish Anti-Glare Satin / Matte Surgical Finish Sterilization Fully Autoclavable up to 134°C Precision Control in Reconstructive Surgery
The Handle Skin Grafting Small is engineered to deliver exceptional tactile balance and accuracy during burn care, trauma reconstruction, and dermatological grafting procedures. Its compact dimensions make this skin grafting knife handle ideal for harvesting uniform epidermal-dermal layers from smaller or curved donor sites where full-length dermatomes are impractical.
Calibrated Roller Guard Assembly
Equipped with precision-machined knurled adjustment screws and a smooth-gliding guard bar, each surgical dermatome handle allows surgeons to fine-tune graft depth consistently across the entire cutting width, minimizing donor-site trauma and promoting rapid re-epithelialization.
Hospital-Grade Metallurgy & Reliability
Forged from surgical stainless steel with a non-reflective satin finish to eliminate operating theater glare, our Humby skin graft blade holder endures repeated ultrasonic cleaning and high-temperature sterilization cycles without mechanical play.
3. Key Features & Surgical Advantages
Compact Small Handle Profile
Shorter working blade span provides superior maneuverability on pediatric patients, limbs, and contoured donor regions.
Micrometer Depth Calibration
Dual knurled adjustment screws lock the roller guard evenly, ensuring consistent split-thickness graft harvesting from edge to edge.
Rigid Quick-Lock Blade Clamp
Precision-fitted locking mechanism holds standard disposable skin graft blades firmly without vibration or slippage during strokes.
Anti-Glare Satin Finish
Matte-finished surgical stainless steel eliminates bright overhead operating room reflections while resisting pitting and rust.
4. Frequently Asked Questions (FAQs)
Q1: When is a small skin grafting handle preferred over a standard large handle?
The small profile is preferred when harvesting grafts from narrower or contoured anatomical regions (such as forearms, lower legs, or pediatric donor sites) requiring heightened control.
Q2: Are disposable skin grafting blades compatible with this handle?
Yes. The handle is machined to accept standard disposable surgical skin grafting blades, ensuring a fresh, razor-sharp cutting edge for every procedure.
Q3: How is graft thickness adjusted on the instrument?
Turning the calibrated knurled screws at either end of the guard adjusts the clearance between the roller bar and blade edge, allowing precise thickness control.
Q4: Can this instrument be sterilized in standard hospital autoclaves?
Yes. Constructed entirely of medical-grade stainless steel, it is fully autoclavable and compatible with standard hospital sterilization protocols.
5. Domestic Supply & Global Export Hubs
Domestic Indian Network
Delhi NCR Maharashtra Uttar Pradesh Karnataka Tamil Nadu Gujarat West BengalNorth & South America
United States (USA) Canada Mexico BrazilEurope & United Kingdom
United Kingdom (UK) Germany FranceMiddle East & Gulf (GCC)
UAE Saudi Arabia Oman Qatar Kuwait
Handle Skin Grafting Small
Corrosion Proof and Highly Reliable for Medical Application.
Made of Stainless Steel.