Product Information
Technical Parameters:
- Model : Floor-standing, High Speed Contrifuge with Compact Footprint.
- Temp. Control Range: - 10°C to 40°C (Adjustable 1°C increments).
- System Range : 15 - 35°C Ambient <= 70 % RH, (Non-condensing)
- Temp. Stability : ± 1°C
- Temp. Accuracy : ± 3°C (Operating speeds)
- Run Modes : Timed, Continuous, & @ Speed Timing
- Chamber Capacity : ≥ 4 L. Capacity (Multiple rotors) Higher sample throughput.
- Speed Accuracy Set : ± 50 RPM, +100 RPM, & + 0.1%
- Overall Dimensions : 40" x 29" X 23" (LxWxH) .
- Display : LCD Digital Display with intuitive Soft-knob key Controls.
- Steps Profile : 3 Nos. Selectable Acceleration & Deceleration profiles.
- Energy Saving : Automatic standby and Eco shut-off Function.
- Input Protection : Compatible with External Voltage Stabiliser.
- Power Supply : 220-240 VAC +10%, 50 Hz, Single-Phase.
- Program Memory : 30 user-Definable programs with Step-run Capability.
- User Management : Access Controlled via password key-lock Function.
- Data Logging : Data Record & Retrieve run logs with Export in GLP Compatible (CSV, PDF) Format.
- Drive System : Brushless with Induction drive Motor (SR, Frequency-Conversion).
- Biosafety : Aerosol-Tight rotor lide Containment Accessories for rotors.
- Rotor Parameter : Display of installed rotor information & Allowable Set Points.
- Certifications : EN 61010-1-2-020 Standard and CE, ISO 9001 with UL Certified
- Connectivity : USB port for Export program & operating log management System.
- Accessories : User and Service Manual, quick Start guide, Power Cable, rotor date sheets & RCF charts
- Lid Safety : Electronic lid lock (Emergency Release) Mechanism During power fuilure.
- Warranty : 3 Year's
FIXED-ANGLE ROTOR 4 X 250 ML
Technical Specifications
- Configuration : Fixed-Angle Rotor 4 x 250 mL pockets rotor configuration with adapters Acceptable, rotor compatibility matrix with pocket count, volume/pocket, adapters, and batch capacity.
- Speed & RCF : Max speed RCF ≥ 20.000 kg (250 mL pockets) with RCF table and validation certificate.
- Bottle Capacity : 4 x 250 mL compatible bottles temp, range -10 °C to +40 °C. Bottle material,
- Rotor Material : Made of high-strength aluminium altoy with corrosion-resistant surface finish with Material & Finish Certified.
- Durability & Life : Life validation data, inspection interval, NDT criteria and allowable Service.
- Biocontainment Aerosol-light lid or certified bio containment accessories
- Cleanability : Rotor & accessories auto clavable (chemically resistant). Sterilization limits and compatibility
- Compatibility Rotor : Fully compatible with contrifuge model adapters.
- Safety Compliance : Rotor and accessories comply with EN 61010-2-420 centrifuge safety standards.
- Traceability : Rotor Serial number with manufacturing traceability, Service Life Details, inspection records, & Rotor FAT Certificate
FIXED-ANGLE ROTOR 50ML
Technical Specifications
- Configuration : Fixed-angle rotor with ≥6 x 50 mL and 28 x 50 mL pockets with adapters.
- Performance : RCF: ≥50,000k g for 50 mL pockets at max. radius with adapters.
- Material : High-strength aluminium alloy composite with Hard-anodised. Chemical-
- Resistant Durability : High-g cycles rotor life inspection intervals, & maintenance schedule.
- Biocontainment : Aerosol-light certified rotor fid containment Accessories Certified
- Cleanability : Rotor pockets, Seals & lids Autoclavable (Chemically resistant).
- Compatibility : Fully Compatible Centrifuge model adapters and provide rotor-Centrifuge Compatibility matris with max, speed limits for each tube combination.
- Safety : Rotor design & manufacturing IEC 60601 Safety standards.
- Traceability : Rotor Serial ID documentation of manufacture date, Service life, inspection Schedule, & End-of-Life Cliteria.
HIGH SPEED 50 ML BOTTLE
Technical Specifications
- Material : High-Clarity Polypropylene (PP) with Caps.
- Capacity : 50 mL nominal capacity with clear graduation marks and fill lines.
- RCF Raning : Rated for RCF ≥ permitted RCF rotor.
- Temp. Range : Suitable for Refrigerated Contriffigation -10°C to +40°C;
- Closure : Leak-proof screw cup with Chemically Resistant Sealing.
- Sterility : Autoclavable.
- Safety : Resistant Resistance with Common lab. buffers & Mild solvents.
- Compatibility : Compatible 50 mL rotor adapters.
- Traceability : Performance Certification with bach traceability.
VACUUM-BASED LIQUID REMOVAL SYSTEM
Technical Specifications
- Filter : Hydrophobic 0.2 µm sterilizable filter.
- Collection Bottle : Autoclavable Polypropylene bottles: 4 L & 2 L capacity.
- Suction Control : Adjustable Suction Controller Mechanical Vacuum Regulator & Integrated Check valve.
- Adapter : 8-Channel Adapter for Multiple Aspiration connections.
- Suction Tubing : Flow Through Suction Tube Compatible Hose Connection.
- Handset & Stand : Aspiration Hand Set Tabletop stand.
- Hose Nozzle Size : 6-10 mm; Outlet Connection 28mm.
- Vacuum Performance : Outlet pressure ≥1.1 bar Suction capacity.
- Motor Power : Motor power ≥40W.
- Construction : Lab liquid Aspiration Autoclavable (Chemically resistant) components.
SUITABLE POWER STABILISER
Technical Specifications
- Capacity : ≥5 kVA Rated input kVA, Suitable for compressor-start-up surge.
- Input Voltage Range : 160-270 VAC
- Output Regulation : 230 V ±1-2% @ Full Load.
- Response Time : Fast Voltage Correction Suitable Compressor & Motor-driven loads.
- Protection : Surge protection, over-voltage, under-voltage, Short-circuit, & overload protection.
- Display : LED Display For input Voltage, output voltage, and load status.
- Duty & Operation : Continuous Duty operation low noise performance.
HIGH SPEED REFRIGERATED CENTRIFUGE
Salient Features:
- CFC-Free, Environment-Compliant refrigeration system Capable of maintaining the Specifed temp. range & stability & operating speeds.
- Automatic rotor imbalance delection with alarm and auto shuf-off.
- Fast precool function Thermal management Features (warmup protection, standly, cooling, eco shut-off).
- Fast PRCF Selection, Run Scheduling, & Quick program recall Facility.
- Automatic identification speed RCF limit control & Secure Rotor Cover
- Detection and rotor-locking mechanism.
- Compatibility with Fixed-Angle Rotors.