  • The apparatus has two transparent tanks, mounted one above the other. 
  • A float switch in the reservoir monitors the level of water. 
  • An in-line flow sensor provides a pulsed output.  
  • A variable-speed pump transfers water from the reservoir into the upper tank. 
  • The water can drain down to the lower tank and then back into the reservoir.
  • Solenoid valves may be individually opened or closed to control and redirect the movement of the water. 
  • The pump control is on or off, but a manual control allows the user to set the speed. 
  • Each tank includes two level sensors which measure maximum and minimum water levels. 
  • Its frequency is proportional to the flow rate and the number of pulses proportional to volume.