Product Information
Plant Physiology & Metabolic Lab ApparatusRespirometer
Precision Volumetric Respirometer Apparatus Featuring Airtight Specimen Chamber, Graduated Capillary Manometer Tube, and Alkali CO2 Absorber Compartment for Measuring Respiration Rates in Germinating Seeds, Plant Tissues, and Small Organisms.
Apparatus Highlights
Calibrated Volumetric Manometer ScaleAirtight Stopper & Specimen ChamberKOH / Soda Lime CO2 Absorption SupportSuitable for Botany & Zoology LabsWhat is a Respirometer?
A Respirometer (also known as a volumetric respirometer apparatus or respiration rate meter) is a laboratory instrument used to measure the rate of respiration of living organisms—such as germinating seeds, respiring plant tissues, yeast, or small invertebrates—by tracking oxygen consumption or carbon dioxide exchange over time. As carbon dioxide released during respiration is absorbed by an alkaline agent (like potassium hydroxide), the resulting pressure drop draws fluid along a calibrated capillary scale to quantify oxygen uptake.
1. Key Features & Design Advantages
Graduated Volumetric Scale
Clearly marked capillary or manometer graduation enables accurate readings of fluid displacement and gas volume changes during timed respiration trials.
Airtight Chamber Sealing
Precision-fitted ground glass or chemical-resistant polymer closures prevent gas leakage, ensuring reliable volumetric measurements across experiments.
CO2 Absorption Readiness
Designed to hold alkaline absorbents safely apart from direct biological specimens so released carbon dioxide is absorbed cleanly without harming samples.
2. Technical Specifications & Overview
Parameter Specification Details Product Name Respirometer (Volumetric Respiration Rate Apparatus) Chamber & Tubing Borosilicate Glass / Heavy-Duty Lab Polymer & Graduated Capillary Measurement Basis Volumetric Fluid Displacement / Manometric Gas Exchange CO2 Absorber Media Compatible with KOH Solution or Soda Lime Pellets Typical Specimens Germinating Seeds, Buds, Small Organisms, & Microbial Cultures Applications Plant Physiology, Cellular Respiration, & Biology Practicals Quantifying Cellular & Plant Respiration
The Respirometer provides a direct, hands-on way for biology students and researchers to observe aerobic respiration in action. By measuring oxygen uptake in germinating seeds or respiring tissues, this volumetric respirometer apparatus helps connect metabolic theory with measurable experimental data.
Reliable Manometric & Volumetric Readouts
Built with clear graduations and stable mounting support, our respiration rate meter makes tracking meniscus movement straightforward during laboratory sessions. Students can compare respiration rates across different temperatures, seed types, or germination stages with clear repeatability.
Institutional Lab Readiness
Manufactured for schools, colleges, and university physiology laboratories, each gas exchange lab equipment unit is inspected for structural integrity and easy cleaning between student batches, supporting dependable practical instruction.
3. Respiration Measurement Protocol
01CO2 Absorber Placement
Place the designated CO2 absorbent (such as soda lime or KOH-soaked cotton/wick) in its compartment without contacting the specimen directly.
02Specimen Loading & Sealing
Introduce weighed germinating seeds or biological material into the chamber and seal the system tightly to prevent air leaks.
03Equilibration & Baseline Reading
Allow thermal equilibration in a stable lab environment, then record the initial fluid position on the graduated scale.
04Timed Readings & Rate Calculation
Record fluid movement at regular time intervals and calculate respiration rate relative to specimen mass and elapsed time.
4. Frequently Asked Questions (FAQs)
Q1: How does a respirometer measure respiration rate?
As organisms consume oxygen and release carbon dioxide, the CO2 absorber removes carbon dioxide from the gas phase, causing a net volume or pressure decrease that moves indicator fluid along a calibrated scale.
Q2: Why is an alkaline CO2 absorber used inside the respirometer?
Without absorbing carbon dioxide, CO2 production would offset oxygen consumption and mask net gas volume changes. Absorbing CO2 isolates the measurable drop due to oxygen uptake.
Q3: What biological samples are commonly tested in student labs?
Germinating bean, pea, or gram seeds, respiring plant buds, and small aquatic or terrestrial organisms are commonly used to demonstrate metabolic activity.
Q4: Why is thermal stability important during a respirometry experiment?
Gases expand or contract with temperature changes; keeping the setup away from direct sunlight, drafts, or heat sources prevents false volume readings.
5. Domestic Supply & Global Export Hubs
Domestic Indian Network
Delhi NCR Maharashtra Uttar Pradesh Karnataka Tamil Nadu Gujarat West BengalNorth & South America
United States (USA) Canada Mexico BrazilEurope & United Kingdom
United Kingdom (UK) Germany FranceMiddle East & Gulf (GCC)
UAE Saudi Arabia Oman Qatar Kuwait
Respirometer
The apparatus consists of two stoppered boiling tubes connected by three way taps to either limb of a graduated manometer.
One tube holds the organisms and has a syringe for altering the level of liquid in the manometer during set up.
The other tube acts as a control thermo-barometer.
C02 given off by the respiring organism is absorbed by potassium hydroxide in the experimental chamber resulting in a change in the level of liquid in the manometer tube.
A compact unit for comparing rates of absorption or evolution of gases by small organisms during respiration.
Technical Specifications :
Complete with wire baskets for supporting organisms.
The apparatus consists of two stoppered boiling tube connected by three-way taps to either limb of graduated manometer.